List of AxisVM messages – Geometry

This article does not contain all possible messages. It contains messages that can occur more or less frequently when using AxisVM.

Categories #

Question from AxisVM to the user if the selected function (e.g. “Delete”) should be carried out or about how to proceed
category_2

Information for the user

category_3

Critical note. Important information, violation of code provisions, untrustworthy results

category_4

Error. The selected function or calculation cannot be performed

category_5

Save. Dialogs to save models and results.

AxisVM MESSAGES #

GEOMETRY #

Képernyőkép 2022-10-18 000943
Save. Dialogs to save models and results.

Cause
Result of the “Geometry Check“. Number of congruent objects. The respective objects have been unified without changing the model

Procedure

    • There is nothing to do

ELEMENTS #

Képernyőkép 2022-10-18 001029
Error. The selected function or calculation cannot be performed

Cause

The selected lines do not create a valid contour for the definition

  • Contour is not a single plane
  • Contour is not closed

Procedure

  • Check geometry and define domain again
  • “Yes” returns to line selection
  • “No” cancels the operation

Cause

The selected reference is not valid for the element (x-reference for domains must not be perpendicular to the domains plane

Procedure

  • Choose a valid reference

unnamed (1)
Question from AxisVM to the user if the selected function (e.g. “Delete”) should be carried out or about how to proceed

Cause

The chosen lines do not form a valid geometry for the insertion of line to line interface elements

  • Lines do not form a quadrangle
  • Quadrangle has nodes along its sides

Procedure

  • Check geometry and define domain again
  • “Yes“ returns to line selection
  • “No“ cancels the operation

Cause

The selected lines form a continuous polygon. Node to node link elements cannot be defined

Procedure

  • Define node-to-node links in multiple steps
  • “Yes” returns to line selection
  • “No” cancels the operation

Cause
When defining line-to-line link elements, not all necessary master nodes have been selected

Procedure

  • “Yes” sets the “interface location” to 0.5, the value cannot be changed
  • “No” allows the selection of new master nodes

 

Powered by BetterDocs